BTS 8000 Battery Testing System

 

Based on the Neware 5th-generation testing system,

BTS 8000 is created for EV (Electric Vehicle) drive cycle simulation.

Quick response ability and multi current ranges ensure extremely high current and power accuracy.

 

 

This is the product image display of Neware BTS8000

 

 

Sample——BTS8000-5V30A Battery Testing System

Items

Values

Input AC

AC 110V/220V ±10% / 50Hz

Input power

 4992 W

Resolution

AD:16bit;DA:16bit

Input impedance

≥1MΩ

Voltage

CV output range

25mV~5V

Mini discharge voltage

1.0V for universial holder,1.5v for 2m cable 

Accuracy

± 0.05% of FS

Stability

± 0.05% of FS

Current

Output range per channel

range1: at least 3A; range2: at least 10% FS;

range 3: at least 50% FS; range4: 100% FS( up to1000A)

Accuracy

± 0.05% of FS

CV cut-off current

range1: range1*0.2%; range2: range2*0.2%

range3: range3*0.2%; range4: range4*0.2%

Stability

± 0.05% of FS

Power

Output power per channel

150W

Stability

± 0.1% of FS

Time

Current response time

Max rising time: 20ms

Working step time

≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)

Data record

Data record conditions

Mini data record interval: 100ms

Mini voltage change:10mV

Mini current change:

range1: range1*0.2%; range2: range2*0.2%

range3: range3*0.2%; range4: range4*0.2%

Frequency

100Hz

Charge

Charge modes

CC、CV、CCCV、CP、Simulation

Cut-off condition

Voltage、Current、Time、Capacity、-△V

Discharge

Discharge modes

CC、CP、CR、CV

Cut-off condition

Voltage、Current、Time、Capacity

 

Pulse

 

 

Charge

CC、CP

Discharge

CC、CP

Min pulse width

500ms

Pulse counts

Up to 32

Chg and Dischg switch

supported

Cut-off condition

Voltage、Time

DICR

Supported

Cycle

Max cycles

65535

Max steps

254

Cycle nest

3

Protection

Safety protection

Power-off data protection

Off-line operation mode

User-defined protection conditions, such as upper and lower limitedcurrent/voltage, delay time, temperature, etc.

Channels feature

Independent pairs of closed loop for constant

Channels control mode

Independent control

Data acquisition method

Kelvin connection

Noise

<85dB

Database

MySQL

Communicatin

TCP/IP

Operating system

Windows 7/8/10 64 bit

Data export

Plain text, xls, pdf, plot/graph

Disk drive

500GB

Communication port

Ethernet port

Leak Current

0.005mA

Channels per unit

16

Operation and storage environment requirement

Items

Values

Operating environment temperature

25±5℃ (guarantee of accuracy) 

25±10℃ (operating limited temperature)

Storage environment temperature

 0℃~60℃

Operating environment humidity

≤70% RH(no moisture condensation)

Storage environment humidity

≤80% RH(no moisture condensation)

Clamps

Clamps types

Universial holders

Other available clamps

●Alligator   ●Polymer   ●Ring connector   ●Universial holders

The-Comparison-Of-Neware-Series