BTS4000 Battery Testing System

BTS 4000 is the most popular series which is based on Neware 4th-generation testing system. It is an update version of BTS 3000.

Comparing with BTS 3000, it has better performance of the same function; also, BTS 4000 can test pulse and HPPC.

Furthermore, it provides higher data acquisition frequency that enable our clients to conduct reliable DCR (Direct Current Resistance) tests.

 

 

 

 

 

This-is-the-image-of-BTS4000-5V10mA-8CH

This-is-the-product-image-display-of-Neware-BTS4000-5V6A

This-is-the-image-of-BTS4000-5V12A

Regular Model

4008-5V10mA、4008-5V20mA、4008-5V50mA、4008-5V6A、

4008-5V12A、4008-5V20A、4008-6V4A、4008-10V3A、4008-10V6A

4008-10V10A、4008-20V10A、4008-15V6A、4008-20V3A、

4008-20V6A、4008-25V3A……

Sample——BTS4000n-5V6A Battery Testing System

Items

Values

Input AC

AC 110V/220V ±10% / 50Hz

Input power

 425 W

Resolution

AD:16bit;DA:16bit

Input impedance

≥1MΩ

Voltage

CV output range

25mV~5V

Mini discharge voltage

1.0V for universial holder,1.5v for 2m cable 

Accuracy

± 0.05% of FS

Stability

± 0.05% of FS

Current

Output range per channel

Range1: 0.5mA; Range2: 0.1A-6A

Accuracy

± 0.05% of FS

CV cut-off current

0.2mA(range1); 12mA(range2)

Stability

± 0.05% of FS

Power

Output power per channel

30W

Stability

± 0.1% of FS

Time

Current response time

Max rising time: 1ms

Working step time

≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)

Data record

Data record conditions

Mini data record interval: 100ms

Mini voltage change:10mV

Mini current change:12mA

Frequency

10Hz

Charge

Charge modes

CC、CV、CCCV、CP

Cut-off condition

Voltage、Current、Time、Capacity、-△V

Discharge

Discharge modes

CC、CP、CR

Cut-off condition

Voltage、Current、Time、Capacity

 

Pulse

 

 

Charge

CC、CP

Discharge

CC、CP

Min pulse width

500ms

Pulse counts

Up to 32

Chg and Dischg switch

supported

Cut-off condition

Voltage、Time

DICR

Supported

Cycle

Max cycles

65535

Max steps

255

Cycle nest

4

Protection

Safety protection

Power-off data protection

Anti-reverse connection 

Off-line operation mode

User-defined protection conditions, such as upper and lower limitedcurrent/voltage, delay time, temperature, etc.

Channels feature

Independent pairs of closed loop for constant

Channels control mode

Independent control

Data acquisition method

Kelvin connection

Noise

<85dB

Database

MySQL

Communicatin

TCP/IP

Operating system

Windows 7/8/10 64 bit

Data export

Plain text, xls, pdf, plot/graph

Disk drive

500GB

Communication port

Ethernet port

Leak Current

0.005mA

Channels per unit

8

Operation and storage environment requirement

Items

Values

Operating environment temperature

0℃~40℃ (When the temperature is 25±10℃, the accuracy error 

caused by temperature change is 50ppm /℃)

Storage environment temperature

 -10℃~50℃

Operating environment humidity

≤70% RH(no moisture condensation)

Storage environment humidity

≤80% RH(no moisture condensation)

Clamps and dimensions

Clamps types

Universial holders

Other available clamps

●Alligator   ●Polymer   ●Ring connector   ●Universial holders

Dimensions(W*D*H)(mm)

3U(164),480*330*130

Close Menu