BTS9000 Battery Testing System

The data of 1000Hz frequency, 0.02% accuracy, and 400μs minimum pulse width proves that BTS 9000,

designed based on the Neware 6th-generation testing system, is the super start series for testing battery or material research.

 

This-is-the-image-of-BTS9000-series

Sample——BTS9000-5V5A Battery Testing System

Items

Values

Input AC

AC 110V/220V ±10% / 50Hz

Input power

 250 W

Resolution

AD:16bit;DA:16bit

Input impedance

≥500MΩ

Voltage

CV output range

charge: 0.7V~4V; discharge: 0.7V~5V(0.5m cable)

Mini discharge voltage

0.7V(0.5m cable)

Accuracy

± 0.02% of FS

Stability

± 0.005% of FS

Current

Output range per channel

range1: 0.1µA~150µA; range2: 150µA~5mA

range3: 5mA~150mA; range4: 150mA~5A

Accuracy

± 0.02% of FS

range1:±30nA; range2: ±1µA

range3: ±30µA; range4: ±1mA

CV cut-off current

range1: range1*0.2%; range1: range1*0.2%

range3: range3*0.2%; range4: range4*0.2%

Stability

± 0.005% of FS

Power

Output power per channel

25W

Stability

± 0.01% of FS

Time

Current response time

≤100µs(10% to 90% or 90% to 10%)

Working step time

≥10ms

Data record

Data record conditions

Mini data record interval: 1ms

Mini voltage change:1mV

Mini current change:100nA

Frequency

1000Hz

Charge

Charge modes

CCC、CVC、CC&CVC、CPC、CRC、Pulse

Cut-off condition

Voltage、Current、Time、Capacity、Power

Discharge

Discharge modes

CCD、CPD、CRD、Pulse

Cut-off condition

Voltage、Current、Time、Capacity

 

Pulse

 

 

Charge

CC、CP

Discharge

CC、CP

Min pulse width

400µs

Pulse counts

Up to 16

Chg and Dischg switch

supported

Cut-off condition

Voltage、Time

DICR

Supported

Cycle

Max cycles

65535

Max steps

255

Cycle nest

4

Protection

Safety protection

Power-off data protection

Off-line operation mode

User-defined protection conditions, such as upper and lower limitedcurrent/voltage, delay time, temperature, etc.

Channels feature

4 ranges, wide dynamic range, high speed sampling, high accuracy

Channels control mode

Independent control

Data acquisition method

Kelvin connection

Noise

<85dB

Database

MySQL

Communicatin

TCP/IP

Operating system

Windows 7/8/10 64 bit

Data export

Plain text, xls, pdf, plot/graph

Disk drive

500GB

Communication port

Ethernet port

Leak Current

0.005mA

Channels per unit

2CH/ 4CH/ 8CH

Operation and storage environment requirement

Items

Values

Operating environment temperature

25±5℃ (guarantee of accuracy)

25±10℃ (operating limited temperature)

Storage environment temperature

 0℃~60℃

Operating environment humidity

≤70% RH(no moisture condensation)

Storage environment humidity

≤80% RH(no moisture condensation)

Clamps and dimensions

Clamps types

Universial holders

Other available clamps

●Alligator   ●Polymer   ●Ring connector   ●Universial holders

Dimensions(W*D*H)(mm)

443*615*125

Close Menu